51195066-100  Honeywell Input module Brand new

51195066-100 Honeywell Input module Brand new

The controller can be mounted in any orientation. 

Ventilation openings are designed into the cover to allow 

proper heat dissipation, regardless of the mounting 

orientation.


Brand:HONEYWELL   Model number 51195066-100

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.22kg

hipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account 

Servce: Professional Sales provides 24 hours /7 days online service

  51195066-100  Honeywell Input module Brand new 

        

image.png


The open wire diagnostic detects and annunciates broken field wires. In addition, a seemingly valid

PV from a channel diagnosed as having a broken-wire will not be made available (thus preventing

incorrect control action). Open Wire Detection is available with AI-HART module.

If open wire detection is enabled (OWDENBL = ON) and the IOM detects the broken-wire condition,

then

l Soft Failure 179 'Open Wire Detected' is generated, and

l PVRAW and PVAUTO will consequently be set to NaN.

ATTENTION

Open wire detection is not supported in AI-HART (Cx-PAIH51) module. The configuration

mismatch warning message appears when you select the OWDENBL option and loads

AICHANNEL FB to AI-HART (Cx-PAIH51) module. After loading the module, the channel can

be activated. However, the OWDENBL parameter value appears as 'FALSE.'

10.12.6 Checking and Filtering PV Range - AI Channel blocks

PV range checking ensures that the PVCALC output of PV characterization is within the limits

defined by parameters PVEXEULO and PVEXEUHI. If either of the limits is violated, the output of

the PVAUTO is set to NaN if clamping has not been specified. If clamping has been specified, the

output of the PVAUTO is clamped to PVEXEUHI or PVEXEULO, except when PVRAW, PVCALC, and

PVAUTO will consequently be set to NaN.

ATTENTION

Honeywell recommends you to configure the current for HLAI (CC-TAIX01) modules from -

6.9% to +102.9% of the 4-to-20 mA range. If you configure the current above +102.9% then

the PVEXEUHI goes to NaN.

If the range-checked and filtered value is less than the value specified by the user-configured

LOCUTOFF parameter, the final output called PVAUTO is forced to PVEULO.



.


.


We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

HONEYWELL    30750338-005    

HONEYWELL    51403393-100    

HONEYWELL    30751044-4    

HONEYWELL    30751044-009    

HONEYWELL    30751044-7    

HONEYWELL    51403393-200    

HONEYWELL    4DP7APXIO211    

HONEYWELL    30750318-2    

HONEYWELL    30750318-3    

HONEYWELL    51196882-100    

HONEYWELL    51304095-100    

HONEYWELL    51400997-200    

HONEYWELL    51401088-100    

HONEYWELL    51400926-100    

HONEYWELL    51304537-100    

HONEYWELL    51401583-200    

HONEYWELL    51401583-100    

HONEYWELL    51401996-100    

HONEYWELL    51304421-100    

HONEYWELL    51304441-175    

HONEYWELL    51107137-117    

HONEYWELL    51196654-100    

HONEYWELL    51196653-100    

HONEYWELL    51400712-100    

HONEYWELL    51204166-175    

HONEYWELL    51401201-100    

HONEYWELL    51401577  



You are welcome to make an inquiry


E-mail:


free@fenoux.com


Tel.:


+86 133 7698 4225


Skype:


+86 133 7698 4225


WhatsApp:


+86 133 7698 4225




Copyright © Hong Kong Saul Electric Co., Ltd. All Rights Reserved Sitemap

Follow Us
Disclaimers: All trademarks on the website are not owned by us. If there is any infrigement, wecan replace them at any time.